1, Open the front protective door of the X-ray inspection equipment (Model S82).
2, Place the bottle onto the 360-degree rotary inspection stage.
3, Close the protective door to engage safety interlock.
4, Activate the X-ray generator.
5, Control the inspection stage rotation and vertical movement using either mouse or control panel.
6, After inspection completion, switch off the X-ray generator.
7, Open the protective door and remove the bottle.
HF-S82 Inspection Process
-
X-ray Tube X-ray Tube Type Microfocus Sealed Tube Maximum
X-ray Tube Voltage
90 kV Maximum
X-ray Tube Current
200 μA X-ray Tube Focal Spot Size 5 μm X-ray Tube Target Power 8 W Detector Detector Type High-Resolution Digital
Flat Panel Detector (FPD)
Detector Resolution 5.8 LP/mm Detector Pixel Size 85 μm Overall Machine Specifications Dimensions 1100mm(L)*1150mm(W)*1700mm(H) Weight 1120kg Power 1100W Stage Stage Size/Dimensions 300 x 300 mm Maximum Stage
Load Capacity/Weight
20 kg Radiation Safety X-ray Leakage
/Radiation Leakage
< 1 μSv/h -